ALSTOM 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 circuit board
ALSTOM 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 circuit board
ALSTOM 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 circuit board

ALSTOM 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 circuit board

1.Warranty time: 1 year

2.Delivery time: 3-5 days

3.Product quality: new or discontinued second-hand

1. We are a global trading company, we have a large stock of spare parts, we also produce energy storage batteries

2. Our main sales products are industrial automation control equipment accessories, such as: controller board, processor module, communication module, input and output module, power module (various circuit boards and cards), touch screen, servo driver, servo motor, sensor, cable......

3. We can not only provide new products, but also supply cold and discontinued spare parts, all the discontinued parts will go through strict testing to ensure the reliability of product performance, so that customers can buy and use at ease

4. For more information, please contact us: Contact: Amy | Email: saul01@qq.com | Tel(WhatsApp/Wechat): +86-15359298283


ALSTOM 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 circuit board(图1)

ALSTOM 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 circuit board(图2)

ALSTOM 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 circuit board(图3)

Key features and functions of the ALSTOM 42011-106-00 A01 include:


Programming Mode: It allows for customization by setting all startup modes to false, enabling customers to program the device. An error check has been implemented to ensure that the rated speed for a generator set is less than the maximum speed.

Service Mode: The minimum load hold has been adjusted to come from the breaker logic harvester input, changing the previous hold change command under the "Speed Control Settings" header.

Speed Setting Ratio: The minimum adjustment range setting point rate for all speeds has been changed to 0.01, down from 0.1.

Auxiliary Limiter or Controller: Logic has been added to ensure auxiliary control in case of input failure. The Aux re-enable logic and the circuit breaker disconnect logic have been modified to correct the generator disconnect auxiliary actuator output fault.

Auxiliary Controller: The speed setpoint auxiliary bias logic has been altered to allow control only when the speed setpoint reaches the maximum control value, preventing control during extreme transient periods.