Flame-ionization detector Fidas24

Measurement principle: Flame-ionization detector

The analyzer complies with the requirements for measuring instruments with flame ionization detection according to EN 12619.

Sample Components and Measurement Ranges

Sample components: Hydrocarbons (THC). The sample component concentration in the sample gas should not exceed 100 % of the LEL.

Number of sample components: 1 sample component

Smallest measurement range:

0–5 to 0–1500 mg org. C/m3 or

0–10 to 0–3000 ppm C1

Largest measurement range:

0–18 to 0–5000 mg org. C/m3 or

0–35 to 0–10000 ppm C1

Measurement range quantity: 2 measurement ranges

Measurement range limits: The measurement range limits can be freely set in the ranges specified above.

Stability

The following data apply only if all influence factors (e.g. flow rate, temperature, atmospheric pressure) are constant. They apply to measurement ranges ≥ 50 mg org. C/m3, for smaller ranges these only apply if they are factory-set per customer order.

Linearity deviation: ≤ 2 % of the span to 5000 mg org. C/m3

This value applies in one (calibrated) measurement range

Repeatability: ≤ 0.5 % of measurement range

Zero-point and sensitivity drift: ≤ 0.5 mg org. C/m3 per week

Output fluctuation (2 σ): ≤ 0.5 % of span at electronic T90 time = 20 sec, not smaller than 10 μg org. C/m3

Detection limit (4 σ): ≤ 1 % of span at electronic T90 time = 20 sec, not smaller than 20 μg org. C/m3

Influence Effects

Oxygen dependence: ≤ 2 % of measured value for 0–21 vol.% O2 or ≤ 0.3 mg org. C/m3, the larger value applies

Temperature effect: Ambient temperature in permissible range at zero-point and on sensitivity: ≤ 2 % per 10 °C in measurement range of 0–15 mg org. C/m3

Pressure effect: No effect of ambient pressure or process pressure fluctuations within the permissible sample gas inlet pressure range

Power supply effect: DC 24 V ± 5 %: ≤ 0.2 % of span or AC 230 V ± 10 %: ≤ 0.2 % of span



ABB EL3020 FIDAS24 other analyzer

ABB EL3020 FIDAS24 other analyzer(图1)


ABB EL3020 FIDAS24 other analyzer


ABB EL3020 FIDAS24 other analyzer(图2)

ABB EL3020 FIDAS24 other analyzer

ABB EL3020 FIDAS24 other analyzer(图3)

ABB EL3020 FIDAS24 other analyzer


You may also want to know about related products:


ABB DDC779BE01 3BHE006805R0001 Excitation redundancy configuration of safety instrument system


ABB INICT01 Input/Output module embedded excitation card central control processing unit


ABB 3BHE019719R0101 GVC736BE101 Communication security controller


ABB G3EFa HENF450295R2 AC servomotor driver



Copyright Beixun Automation All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.