Tektronix TCPA300 current probe
Tektronix TCPA300 current probe
Tektronix TCPA300 current probe

Tektronix TCPA300 current probe

1.Warranty time: 1 year

2.Delivery time: 3-5 days

3.Product quality: new or discontinued second-hand

1. We are a global trading company, we have a large stock of spare parts, we also produce energy storage batteries

2. Our main sales products are industrial automation control equipment accessories, such as: controller board, processor module, communication module, input and output module, power module (various circuit boards and cards), touch screen, servo driver, servo motor, sensor, cable......

3. We can not only provide new products, but also supply cold and discontinued spare parts, all the discontinued parts will go through strict testing to ensure the reliability of product performance, so that customers can buy and use at ease

4. For more information, please contact us: Contact: Amy | Email: saul01@qq.com | Tel(WhatsApp/Wechat): +86-15359298283


Tektronix TCPA300 current probe


Tektronix TCPA300 current probe


TCP300 and TCP400 series AC/DC current measurement series are the best current measurement systems to meet today's current measurement needs. When TEKPROBE Level II, TekConnect (using TCA-BNC) or TekVPI (using TPA-BNC) interfaces are connected to TekProbe oscilloscopes, current measurements and calculations are easy and simple.


Main performance index


AC/DC measurement function


DC-100 MHz, Current Probe Amplifier (TCPA300) uses:


Dc-100 MHz, 30 A DC (TCP312A)


Dc-50 MHz, 50 A DC (TCP305A)


Dc-15 MHz, 150 A DC (TCP303)


DC-50 MHz, Current Probe Amplifier (TCPA400) uses:


Dc-2 MHz, 750 A DC 1 (TCP404XL) (500 A DC continuous current)


1 The derating is related to duty cycle


Tektronix TCPA300 current probe


Main feature


Automatic calibration and determination of the amplitude and current reading of the unit 1 - oscilloscope screen reduces measurement errors by eliminating manual calculations


AC/DC input coupling


Low insertion impedance reduces the load on the device under test


Split core structure, simple circuit connection


The status indicator provides notification of virtual operating status and potential error conditions - demagnetization, probe length, overload, misconnection 50 incompatible probe types


Dc drift and noise are reduced for improved low-level current measurement


Third-party security certification


1 Requires a TDS TEKSCOPE oscilloscope or a TekConnect oscilloscope with a TCA-BNC adapter


Apply


Development and analytical solutions for designers, installers and maintainers in the telecommunications, data communications, computer and semiconductor power electronics environmental protection industries:


Power supply (switching and linear)


Semiconductor devices (SCR, IGBT, MOSFET, CMOS, BJT)


Power inverter/converter


Electronic ballast


Industrial/consumer electronics


Mobile communications (telephone, satellite, relay station)


Motor driver


Transportation systems (electric vehicles, electric trains, locomotives, avionics)


Meet today's AC/DC current measurement applications


When used with TCP312A, TCP305A, or TCP303 probes, the TCPA300 amplifier provides a range of current measurement capabilities that bridge the gap between low-current measurement products and ultra-high current measurement products. These three probes provide current measurement for 30 A, 50 A, and 150 A continuous DC currents. For higher current levels, the TCPA400 amplifier with the TCP404XL current probe can measure continuous DC currents at 500A and 750A, with derating related to duty cycle.


TCP312A with TCPA300 achieves higher frequency performance, providing ≥100 MHz bandwidth and up to 30A DC current.


Total elimination of measurement errors and manual calculation work


The new series of current measuring tools are Tektronix TDS3000, TDS500, TDS600, TDS700, TDS5000, TDS6000 and TDS7000B Users of the series oscilloscope system are provided with automatic control functions and screen scales and units (DPO3000, MDO/MSO/DPO4000, MSO/DPO5000 and DPO7000 series oscilloscopes require a TPA-BNC adapter).


The TCP300/TCP400 current measurement system can be seamlessly integrated with the TDS series oscilloscope.


Even the non-TekProbe system can also use the TCPA300/400 series to perform the corresponding current measurement, the user only needs to multiply the output voltage measured on the oscilloscope by the TCPA300/400 series range setting value.


Technical data


All technical specifications are guaranteed unless otherwise stated. All specifications apply to all models unless otherwise stated.


Model overview


TCP312A with TCPA300 TCP305A with TCPA300 TCP303 with TCPA400 TCP404XL

Bandwidth DC-100 MHz DC-50 MHz DC-15 MHz DC-2 MHz

Rise time ≤3.5 ns ≤7 ns ≤23 ns ≤175 ns

Dc accuracy ±3% of readings ±3% of readings ±3% of readings ±3% of readings ±3% of readings

Accuracy (typical value) DC: reading ±1%DC to 60 Hz, ≤5 A: ±1%

60 Hz - 5 kHz, ≤5 A: ±1.5%


Dc-5 kHz, >5 A: ±1.5%


DC: Reading ±1%DC to 60 Hz, ≤5 A: ±1%

60 Hz - 5 kHz, ≤5 A: ±1.5%


Dc-5 kHz, >5 A: ±1.5%


Dc: ±1% of reading DC: ±1% of reading

Small measuring current (DC accuracy ±3%)

The oscilloscope is set to 1 mV/ cell and the bandwidth is limited to 20 MHz


1 mA 5 mA 5 mA 1 A

Typical large ampere-second product (based on amplifier range Settings) 50 A*μS - 1 A/V

500 A*μS - 10 A/V


500 A*μS - 5 A/V

Not applicable - 10 A/V


3,000 A*μS - 5 A/V

15000 A*μS - 50 A/V


Not applicable - 1 A/V

High line voltage

Bare wire 150 V CAT II 150 V CAT II 600 V CAT I and II 600 V CAT I and II

Insulated cable 300 V CAT II 300 V CAT II 300 V CAT III 300 V CAT III

Typical AC coupling low frequency bandwidth (low-pass - 3 dB points) < 7 Hz < 7 Hz < 7 Hz < 7 Hz < 7 Hz

Typical RMS noise shown (20 MHz bandwidth limit) ≤250 μARMS ≤1.25 mARMS ≤2.5 mARMS ≤250 mARMS

Signal delay (to output BNC) 17 ns 19 ns 40 ns 80 ns

0.11 when insertion impedance is 1 MHz? 0.12 at 10 MHz?

0.35 at 50 MHz?


0.7 at 100 MHz?


0.02 at 1 MHz? 0.1 at 10 MHz?

0.35 at 50 MHz?


0.01 at 1 MHz?

0.025 at 5 MHz?


0.1 at 15 MHz?


0.1 m at 10 kHz?

0.6 m at 100 kHz?


8 m at 1 MHz?


16 m at 2 MHz?


peculiarity


High current rating:


High current sensitivity


TCP312A with TCPA300 TCP305A with TCPA300 TCP303 with TCPA400 TCP404XL

Range 10 A/V 10 A/V 50 A/V 1 A/mV

DC (Continuous current) 30 A 50 A 150 A 500 A (750 A)

RMS (sine) 21.2 A 35.4 A 150 A 500 A

Peak 50 A 50 A 500 A 750 A

Low current sensitivity


TCP312A with TCPA300 TCP305A with TCPA300 TCP303 with TCPA400 TCP404XL

Radius


Tektronix TCPA300 current probe

Tektronix TCPA300 current probe(图1)


Tektronix TCPA300 current probe


Tektronix TCPA300 current probe(图2)

Tektronix TCPA300 current probe

Tektronix TCPA300 current probe(图3)


Tektronix TCPA300 current probe

MAIN PRODUCT :


ABB: Industrial robot spare parts DSQC series, Bailey INFI 90, IGCT, etc., for example: 5SHY6545L0001 AC10272001R0101 5SXE10-0181,5SHY3545L0009,5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512 a10-15000 3BHE040375R1023, PPD113, PP836A, PP865A, PP877, PP881, PP885,etc.,




GE: spare parts such as modules, cards, and drivers. For example: VMIVME-7807, VMIVME-7750, WES532-111, UR6UH, SR469-P5-HI-A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A , IC698CPE010,IS200SRTDH2ACB,etc.,






Bently Nevada: 3500/3300/1900 system, Proximitor probe, etc.,for example: 3500/22M,3500/32, 3500/15, 3500/20,3500/42M,1900/27,etc.,




Invensys Foxboro: I/A series of systems, FBM sequence control, ladder logic control, incident recall processing, DAC, input/output signal processing, data communication and processing, such as FCP270 and FCP280,P0904HA,E69F-TI2-S,FBM230/P0926GU,FEM100/P0973CA,etc.,




Invensys Triconex: power module,CPU Module,communication module,Input output module,such as 3008,3009,3009X,3720,3721,4351B,3805E,8312,3511,4355X,etc.,



Copyright Beixun Automation All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.